{"id":23656,"date":"2023-03-15T12:34:02","date_gmt":"2023-03-15T11:34:02","guid":{"rendered":"https:\/\/heat-me.poush-dev.be\/codes_erreur\/foutcode-bosch-ea-ea-227\/"},"modified":"2025-04-23T12:07:08","modified_gmt":"2025-04-23T10:07:08","slug":"foutcode-bosch-ea-ea-227","status":"publish","type":"codes_erreur","link":"https:\/\/www.heat-me.be\/nl\/codes_erreur\/foutcode-bosch-ea-ea-227\/","title":{"rendered":"Foutcode &#8211; Bosch &#8211; EA EA 227"},"content":{"rendered":"<div class=\"custom-code-erreur-content\">\n<h2 class=\"h3-size\">Beschrijving<\/h2>\n<p>De vlam wordt niet herkend.<\/p>\n<h2 class=\"h3-size\">Oplossing<\/h2>\n<ul>\n<li>Na de 4e ontstekingspoging wordt de blokkeringsfout omgezet in een vergrendelingsfout.<\/li>\n<li>Controleer of de gaskraan open staat.<\/li>\n<li>Controleer de druk van de gasaansluiting.<\/li>\n<li>Controleer de netaansluiting.<\/li>\n<li>Controleer de elektroden en kabels en vervang ze indien nodig.<\/li>\n<li>Controleer het rookafvoersysteem en reinig of repareer het indien nodig.<\/li>\n<li>Controleer de lucht-gasverhouding en corrigeer indien nodig.<\/li>\n<li>Aardgas: controleer de externe gasstroomregelaar en vervang deze indien nodig.<\/li>\n<li>Reinig de condensaatafvoer.<\/li>\n<li>Verwijder het membraan in de ventilatormengwagen en controleer het op scheuren en vuil.<\/li>\n<li>Maak het verwarmingselement schoon.<\/li>\n<li>Controleer het gasblok en vervang het indien nodig.<\/li>\n<li>Controleer bij ketels die afhankelijk zijn van omgevingslucht het verbrandingsluchtblok of de luchtopeningen.<\/li>\n<\/ul>\n<h2><\/h2>\n<h2 class=\"h3-size\">Standaard categorie<\/h2>\n<p>B V<\/p>\n<h2><\/h2>\n<h2 class=\"h3-size\">Categorie<\/h2>\n<p>7000i-serie vanaf 2017<\/p><\/div>\n<p>[vc_widget_sidebar show_bg=&#8221;false&#8221; sidebar_id=&#8221;sidebar_7&#8243;]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Beschrijving De vlam wordt niet herkend. Oplossing Na de 4e ontstekingspoging wordt de blokkeringsfout omgezet in een vergrendelingsfout. Controleer of de gaskraan open staat. Controleer de druk van de gasaansluiting. Controleer de netaansluiting. Controleer de elektroden en kabels en vervang ze indien nodig. Controleer het rookafvoersysteem en reinig of repareer het indien nodig. Controleer de&hellip;<\/p>\n","protected":false},"author":3,"featured_media":9502,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","format":"standard","meta":{"inline_featured_image":false,"footnotes":""},"code_erreur_categorie":[34,53],"class_list":["post-23656","codes_erreur","type-codes_erreur","status-publish","format-standard","has-post-thumbnail","hentry","code_erreur_categorie-bosch","code_erreur_categorie-serie-7000i-a-partir-de-2017","description-off"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Foutcode - Bosch - EA EA 227 - Heat Me<\/title>\n<meta name=\"description\" content=\"Foutcode - Bosch - EA EA 227 | Besoin d\u2019un technicien pour une r\u00e9paration ou un d\u00e9pannage de votre chaudi\u00e8re ? Heat Me va vous aider !\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.heat-me.be\/nl\/codes_erreur\/foutcode-bosch-ea-ea-227\/\" \/>\n<meta property=\"og:locale\" content=\"nl_NL\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Foutcode - Bosch - EA EA 227 - Heat Me\" \/>\n<meta property=\"og:description\" content=\"Foutcode - Bosch - EA EA 227 | Besoin d\u2019un technicien pour une r\u00e9paration ou un d\u00e9pannage de votre chaudi\u00e8re ? Heat Me va vous aider !\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.heat-me.be\/nl\/codes_erreur\/foutcode-bosch-ea-ea-227\/\" \/>\n<meta property=\"og:site_name\" content=\"Heat Me\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/heatme.officiel\" \/>\n<meta property=\"article:modified_time\" content=\"2025-04-23T10:07:08+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.heat-me.be\/wp-content\/uploads\/2023\/01\/heat-me-condens-gc-2300iw-2.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1000\" \/>\n\t<meta property=\"og:image:height\" content=\"1000\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Geschatte leestijd\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minuut\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.heat-me.be\\\/nl\\\/codes_erreur\\\/foutcode-bosch-ea-ea-227\\\/\",\"url\":\"https:\\\/\\\/www.heat-me.be\\\/nl\\\/codes_erreur\\\/foutcode-bosch-ea-ea-227\\\/\",\"name\":\"Foutcode - Bosch - EA EA 227 - Heat Me\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.heat-me.be\\\/nl\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.heat-me.be\\\/nl\\\/codes_erreur\\\/foutcode-bosch-ea-ea-227\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.heat-me.be\\\/nl\\\/codes_erreur\\\/foutcode-bosch-ea-ea-227\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.heat-me.be\\\/wp-content\\\/uploads\\\/2023\\\/01\\\/heat-me-condens-gc-2300iw-2.png\",\"datePublished\":\"2023-03-15T11:34:02+00:00\",\"dateModified\":\"2025-04-23T10:07:08+00:00\",\"description\":\"Foutcode - Bosch - EA EA 227 | Besoin d\u2019un technicien pour une r\u00e9paration ou un d\u00e9pannage de votre chaudi\u00e8re ? Heat Me va vous aider !\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.heat-me.be\\\/nl\\\/codes_erreur\\\/foutcode-bosch-ea-ea-227\\\/#breadcrumb\"},\"inLanguage\":\"nl-NL\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.heat-me.be\\\/nl\\\/codes_erreur\\\/foutcode-bosch-ea-ea-227\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"nl-NL\",\"@id\":\"https:\\\/\\\/www.heat-me.be\\\/nl\\\/codes_erreur\\\/foutcode-bosch-ea-ea-227\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.heat-me.be\\\/wp-content\\\/uploads\\\/2023\\\/01\\\/heat-me-condens-gc-2300iw-2.png\",\"contentUrl\":\"https:\\\/\\\/www.heat-me.be\\\/wp-content\\\/uploads\\\/2023\\\/01\\\/heat-me-condens-gc-2300iw-2.png\",\"width\":1000,\"height\":1000,\"caption\":\"Photo de la chaudi\u00e8re Bosch Condens GC 2300iW\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.heat-me.be\\\/nl\\\/codes_erreur\\\/foutcode-bosch-ea-ea-227\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Accueil\",\"item\":\"https:\\\/\\\/www.heat-me.be\\\/nl\\\/accueil\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Foutcode &#8211; Bosch &#8211; EA EA 227\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.heat-me.be\\\/nl\\\/#website\",\"url\":\"https:\\\/\\\/www.heat-me.be\\\/nl\\\/\",\"name\":\"Heat Me\",\"description\":\"Heating, Plumbing, Relaxing\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.heat-me.be\\\/nl\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.heat-me.be\\\/nl\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"nl-NL\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.heat-me.be\\\/nl\\\/#organization\",\"name\":\"Heat me\",\"url\":\"https:\\\/\\\/www.heat-me.be\\\/nl\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"nl-NL\",\"@id\":\"https:\\\/\\\/www.heat-me.be\\\/nl\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.heat-me.be\\\/wp-content\\\/uploads\\\/2023\\\/01\\\/cropped-heat-me-favicon.png\",\"contentUrl\":\"https:\\\/\\\/www.heat-me.be\\\/wp-content\\\/uploads\\\/2023\\\/01\\\/cropped-heat-me-favicon.png\",\"width\":512,\"height\":512,\"caption\":\"Heat me\"},\"image\":{\"@id\":\"https:\\\/\\\/www.heat-me.be\\\/nl\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/heatme.officiel\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Foutcode - Bosch - EA EA 227 - Heat Me","description":"Foutcode - Bosch - EA EA 227 | Besoin d\u2019un technicien pour une r\u00e9paration ou un d\u00e9pannage de votre chaudi\u00e8re ? Heat Me va vous aider !","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.heat-me.be\/nl\/codes_erreur\/foutcode-bosch-ea-ea-227\/","og_locale":"nl_NL","og_type":"article","og_title":"Foutcode - Bosch - EA EA 227 - Heat Me","og_description":"Foutcode - Bosch - EA EA 227 | Besoin d\u2019un technicien pour une r\u00e9paration ou un d\u00e9pannage de votre chaudi\u00e8re ? Heat Me va vous aider !","og_url":"https:\/\/www.heat-me.be\/nl\/codes_erreur\/foutcode-bosch-ea-ea-227\/","og_site_name":"Heat Me","article_publisher":"https:\/\/www.facebook.com\/heatme.officiel","article_modified_time":"2025-04-23T10:07:08+00:00","og_image":[{"width":1000,"height":1000,"url":"https:\/\/www.heat-me.be\/wp-content\/uploads\/2023\/01\/heat-me-condens-gc-2300iw-2.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Geschatte leestijd":"1 minuut"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.heat-me.be\/nl\/codes_erreur\/foutcode-bosch-ea-ea-227\/","url":"https:\/\/www.heat-me.be\/nl\/codes_erreur\/foutcode-bosch-ea-ea-227\/","name":"Foutcode - Bosch - EA EA 227 - Heat Me","isPartOf":{"@id":"https:\/\/www.heat-me.be\/nl\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.heat-me.be\/nl\/codes_erreur\/foutcode-bosch-ea-ea-227\/#primaryimage"},"image":{"@id":"https:\/\/www.heat-me.be\/nl\/codes_erreur\/foutcode-bosch-ea-ea-227\/#primaryimage"},"thumbnailUrl":"https:\/\/www.heat-me.be\/wp-content\/uploads\/2023\/01\/heat-me-condens-gc-2300iw-2.png","datePublished":"2023-03-15T11:34:02+00:00","dateModified":"2025-04-23T10:07:08+00:00","description":"Foutcode - Bosch - EA EA 227 | Besoin d\u2019un technicien pour une r\u00e9paration ou un d\u00e9pannage de votre chaudi\u00e8re ? Heat Me va vous aider !","breadcrumb":{"@id":"https:\/\/www.heat-me.be\/nl\/codes_erreur\/foutcode-bosch-ea-ea-227\/#breadcrumb"},"inLanguage":"nl-NL","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.heat-me.be\/nl\/codes_erreur\/foutcode-bosch-ea-ea-227\/"]}]},{"@type":"ImageObject","inLanguage":"nl-NL","@id":"https:\/\/www.heat-me.be\/nl\/codes_erreur\/foutcode-bosch-ea-ea-227\/#primaryimage","url":"https:\/\/www.heat-me.be\/wp-content\/uploads\/2023\/01\/heat-me-condens-gc-2300iw-2.png","contentUrl":"https:\/\/www.heat-me.be\/wp-content\/uploads\/2023\/01\/heat-me-condens-gc-2300iw-2.png","width":1000,"height":1000,"caption":"Photo de la chaudi\u00e8re Bosch Condens GC 2300iW"},{"@type":"BreadcrumbList","@id":"https:\/\/www.heat-me.be\/nl\/codes_erreur\/foutcode-bosch-ea-ea-227\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Accueil","item":"https:\/\/www.heat-me.be\/nl\/accueil\/"},{"@type":"ListItem","position":2,"name":"Foutcode &#8211; Bosch &#8211; EA EA 227"}]},{"@type":"WebSite","@id":"https:\/\/www.heat-me.be\/nl\/#website","url":"https:\/\/www.heat-me.be\/nl\/","name":"Heat Me","description":"Heating, Plumbing, Relaxing","publisher":{"@id":"https:\/\/www.heat-me.be\/nl\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.heat-me.be\/nl\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"nl-NL"},{"@type":"Organization","@id":"https:\/\/www.heat-me.be\/nl\/#organization","name":"Heat me","url":"https:\/\/www.heat-me.be\/nl\/","logo":{"@type":"ImageObject","inLanguage":"nl-NL","@id":"https:\/\/www.heat-me.be\/nl\/#\/schema\/logo\/image\/","url":"https:\/\/www.heat-me.be\/wp-content\/uploads\/2023\/01\/cropped-heat-me-favicon.png","contentUrl":"https:\/\/www.heat-me.be\/wp-content\/uploads\/2023\/01\/cropped-heat-me-favicon.png","width":512,"height":512,"caption":"Heat me"},"image":{"@id":"https:\/\/www.heat-me.be\/nl\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/heatme.officiel"]}]}},"_links":{"self":[{"href":"https:\/\/www.heat-me.be\/nl\/wp-json\/wp\/v2\/codes_erreur\/23656","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.heat-me.be\/nl\/wp-json\/wp\/v2\/codes_erreur"}],"about":[{"href":"https:\/\/www.heat-me.be\/nl\/wp-json\/wp\/v2\/types\/codes_erreur"}],"author":[{"embeddable":true,"href":"https:\/\/www.heat-me.be\/nl\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.heat-me.be\/nl\/wp-json\/wp\/v2\/comments?post=23656"}],"version-history":[{"count":11,"href":"https:\/\/www.heat-me.be\/nl\/wp-json\/wp\/v2\/codes_erreur\/23656\/revisions"}],"predecessor-version":[{"id":23697,"href":"https:\/\/www.heat-me.be\/nl\/wp-json\/wp\/v2\/codes_erreur\/23656\/revisions\/23697"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.heat-me.be\/nl\/wp-json\/wp\/v2\/media\/9502"}],"wp:attachment":[{"href":"https:\/\/www.heat-me.be\/nl\/wp-json\/wp\/v2\/media?parent=23656"}],"wp:term":[{"taxonomy":"code_erreur_categorie","embeddable":true,"href":"https:\/\/www.heat-me.be\/nl\/wp-json\/wp\/v2\/code_erreur_categorie?post=23656"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}